Acoustic enclosures and upward-discharge silencers for rooftop food-service equipment
The enclosure and exhaust silencer were designed as one system. This kept the discharge path open and upward while controlling leakage through the enclosure walls, doors and service interfaces.
Project Profile
|
Location |
Nanjing, China |
|
Industry |
Commercial retail and food service |
|
Primary noise sources |
Four rooftop kitchen exhaust units |
|
Baseline condition |
Approximately 96 dB(A) beside the operating exhaust fans; up to 64 dB(A) inside tenant areas |
|
Applicable standard or target |
GB 22337-2008 Class II area for social-life environmental noise |


Project Challenge
The exhaust equipment was directly above occupied tenant areas. The noise-control system had to reduce structure-borne and airborne noise while keeping smoke exhaust performance and maintenance access available.
Engineered Solution
- Installed three composite acoustic enclosures around adjacent equipment groups, using a structure rated at ≥ 30 dB sound insulation.
- Added impedance-composite exhaust silencers with upward discharge, rain caps and directional exhaust ducts, designed for ≥ 20 dB attenuation.
- Provided acoustic access doors rated at ≥ 30 dB.
- Removed part of the original vertical ductwork to create the installation space required for the new silencing system.
- Used a multilayer enclosure consisting of aluminum sheet, damping acoustic board, 100 mm 100K acoustic wool, non-alkali glass cloth and perforated aluminum facing.
Performance Targets And Results
|
Metric |
Target or value |
Project interpretation |
|
Tenant-area noise |
Reduced to meet the Class II requirement |
Target performance |
|
Enclosure insertion loss |
≥ 25 dB(A) |
Design target |
|
Exhaust performance |
Airflow and pressure maintained |
Smoke extraction unaffected |