Integrated Noise Control for an Industrial Oxygen Production Station

Sep 22, 2026 Leave a message

Building enclosure, opening treatment and silencer-tower upgrades for a high-noise gas facility

The project illustrates an integrated noise-control strategy: the building envelope, ventilation openings and exhaust tower were treated as connected parts of one acoustic system.

 

Project Profile

 

Location

Chongqing, China

Industry

Industrial gas and oxygen production

Primary noise sources

Oxygen compressors, vacuum pumps, blowers, filters, oxygen tanks and a silencer tower

Baseline condition

Equipment noise of approximately 105-120 dB(A), affecting personnel and the surrounding plant boundary

Applicable standard or target

GB 12348-2008 Class III boundary target: daytime ≤ 65 dB(A), nighttime ≤ 55 dB(A); plant exterior target at 1 m ≤ 85 dB(A)

image001
Before Treatment
image003
After Treatment

Project Challenge

 

The facility combined several high-noise sources with necessary ventilation openings and a tall exhaust tower. The treatment needed to address the building envelope and the point sources together, with reliable sealing between modular panels.

 

Engineered Solution

 

  • Enclosed the process building with a 100 mm composite sound-absorbing and sound-insulating system rated at ≥ 35 dB.
  • Provided acoustic treatment for reserved air openings and ventilation outlets to prevent leakage through the ventilation route.
  • Upgraded the silencer tower with a 100 mm composite enclosure at the top and a custom exhaust silencer system, designed for ≥ 35 dB attenuation.
  • Carried out an acoustic retrofit of the existing pressure-relief silencer.
  • Used interlocking modular panel joints to achieve close, continuous installation and reduce sound leakage at connections.

 

Performance Targets And Results

 

Metric

Target or value

Project interpretation

Plant exterior noise

≤ 85 dB(A) at 1 m

Project target

Northern boundary noise

Daytime ≤ 65 dB(A); nighttime ≤ 55 dB(A)

Designed for Class III compliance

Silencer tower reduction

≥ 35 dB(A)

Design target

Acceptance support

Performance verification included in the project scope

Commissioning-oriented delivery

 