Projects

Compressor and Nitrogen Compressor Room Noise Control at an Energy Facility

Sep 22, 2026 Leave a message

A walk-in acoustic enclosure with forced ventilation, observation windows and protected process piping

For high-energy industrial rooms, acoustic performance cannot be separated from heat removal and safety. The enclosure, silencer sizing, forced ventilation and temperature control were developed together.

 

Project Profile

 

Location

Ningxia, China

Industry

Coal chemical and energy production

Primary noise sources

Gas turbine, air compressors, booster compressors and process piping in compressor rooms

Baseline condition

Approximately 105-113 dB(A) in the operating areas

Applicable standard or target

GBZ 2.2-2007 occupational exposure limits; target noise outside the treatment at 1 m ≤ 85 dB(A)

image001
Before Treatment 
info-800-600
After Treatment

Project Challenge

 

The equipment generated high continuous noise and substantial heat. The enclosure had to provide a safe working environment while preserving operator access, thermal control, explosion-protection requirements and visibility of the equipment.

 

Engineered Solution

 

  • Built a walk-in composite acoustic enclosure around the air compressor, turbine and booster compressor groups, with internal circulation space.
  • Added multiple 1 m x 2 m acoustic doors rated at ≥ 30 dB for inspection and maintenance.
  • Installed 12 intake and 12 exhaust silencer units, each approximately 1500 x 1000 x 1500 mm, designed for ≥ 25 dB attenuation and arranged for lower-inlet and upper-exhaust convection.
  • Added explosion-protected axial fans and an automatic temperature-sensing control system to regulate ventilation.
  • Installed 24 double laminated tempered acoustic observation windows rated at ≥ 20 dB.
  • Wrapped process piping with a three-layer system combining thermal insulation, acoustic treatment and mechanical protection.

 

Performance Targets And Results

 

Metric

Target or value

Project interpretation

Work-area noise target

≤ 85 dB(A) at 1 m outside the treatment

Occupational-health target

Enclosure insertion loss

Approximately 20-28 dB(A)

Design performance range

Safety and operation

Ventilation and explosion-protection requirements maintained

Normal production preserved

 

Send Inquiry