Factory-made modular enclosures for fast installation around five operating fans
The modular factory-made approach reduced site work and made the retrofit practical for an operating medical-equipment facility, while the removable roof and sealed penetrations supported long-term maintenance.
Project Profile
|
Location |
Nanjing, China |
|
Industry |
Medical and biotechnology equipment |
|
Primary noise sources |
Five negative-pressure fans serving the production area |
|
Baseline condition |
Approximately 82 dB(A) measured around the operating equipment |
|
Applicable standard or target |
Project target outside the enclosure at 1 m: ≤ 70 dB(A) |


Project Challenge
The fans were installed in an active production environment, so the retrofit had to be compact, quick to assemble and easy to reopen for equipment maintenance. The original fan openings also had to remain functional.
Engineered Solution
- Designed five individual acoustic enclosures using 50 mm composite sound-absorbing and sound-insulating modules manufactured in the factory for rapid site assembly.
- Used a 1.5 mm 304 stainless-steel outer skin, damping acoustic layer, 50 mm acoustic wool sealed with glass-fiber facing cloth and 0.6 mm perforated aluminum inner facing.
- Added a compact axial-fan exhaust system to remove heat and maintain normal equipment operation.
- Designed removable roof sections for equipment inspection and maintenance.
- Connected the enclosure intake and exhaust openings to the existing fan openings without obstructing the fan duty point.
- Applied professional acoustic sealing around pipe and duct penetrations to prevent leakage.
Performance Targets And Results
|
Metric |
Target or value |
Project interpretation |
|
Noise outside the enclosure |
≤ 70 dB(A) at 1 m |
Project target |
|
Enclosure insertion loss |
≥ 12 dB(A) |
Design target |
|
Installation |
Assembly completed within two days |
Limited impact on production |