Large-scale exhaust silencing and a 498 m acoustic barrier for 86 roof-level fans
The project combined point-source treatment at every exhaust outlet with a long boundary barrier. Acoustic simulation was used to verify the interaction between the two measures before implementation.
Project Profile
|
Location |
Yiwu, Zhejiang, China |
|
Industry |
Photovoltaic and renewable energy manufacturing |
|
Primary noise sources |
Eighty-six hot-air centrifugal exhaust fans on a 6 m high steel platform; fan, motor, gearbox and aerodynamic outlet noise |
|
Baseline condition |
Nighttime boundary noise of approximately 75-80 dB(A), with a maximum exceedance of about 26 dB(A); fan body 91.3 dB(A) and outlet 102.4 dB(A) |
|
Applicable standard or target |
GB 12348-2008 Class IV area: daytime ≤ 70 dB(A), nighttime ≤ 55 dB(A) |
|
Project status |
Design-stage case with performance targets verified through Cadna/A acoustic simulation |


Project Challenge
The project involved a large number of high-flow exhaust outlets operating on an elevated platform. The solution had to provide substantial attenuation while keeping pressure loss low enough to protect fan airflow and heat removal.
Engineered Solution
- Added exhaust silencers to all 86 fan outlets, designed for ≥ 25 dB(A) attenuation with total pressure loss ≤ 60 Pa.
- Used a casing of 2.0 mm galvanized steel with a structural frame, 24 kg/m3 glass wool infill and 0.8 mm galvanized perforated inner facing.
- Added dual flow-guiding heads and rain-protection acoustic caps to support low-loss discharge and weather resistance.
- Installed an approximately 498 m long, 7 m high acoustic barrier along the north side of the steel platform, with panel weighted sound insulation Rw ≥ 30 dB.
- Used 100 mm acoustic splitters with approximately 150 mm spacing; typical silencer dimensions were approximately 1410 x 1820 x 3200 mm including the rain cap.
- Provided powder-coated flow-guide ends, steel support structures, maintenance walkways and safety protection.
Performance Targets And Results
|
Metric |
Target or value |
Project interpretation |
|
Boundary noise target |
Daytime ≤ 70 dB(A); nighttime ≤ 55 dB(A) |
Designed for Class IV compliance |
|
Outlet silencer attenuation |
≥ 25 dB(A) |
Design target |
|
Barrier reduction |
Approximately 15-24 dB(A) |
Simulation-based range |
|
Pressure loss |
≤ 60 Pa |
Fan ventilation and heat removal maintained |