Boundary Noise Control for a Photovoltaic Manufacturing Plant

Sep 22, 2026 Leave a message

Large-scale exhaust silencing and a 498 m acoustic barrier for 86 roof-level fans

The project combined point-source treatment at every exhaust outlet with a long boundary barrier. Acoustic simulation was used to verify the interaction between the two measures before implementation.

 

Project Profile

 

Location

Yiwu, Zhejiang, China

Industry

Photovoltaic and renewable energy manufacturing

Primary noise sources

Eighty-six hot-air centrifugal exhaust fans on a 6 m high steel platform; fan, motor, gearbox and aerodynamic outlet noise

Baseline condition

Nighttime boundary noise of approximately 75-80 dB(A), with a maximum exceedance of about 26 dB(A); fan body 91.3 dB(A) and outlet 102.4 dB(A)

Applicable standard or target

GB 12348-2008 Class IV area: daytime ≤ 70 dB(A), nighttime ≤ 55 dB(A)

Project status

Design-stage case with performance targets verified through Cadna/A acoustic simulation

image001
Before Treatment
image003
After Treatment

Project Challenge

 

The project involved a large number of high-flow exhaust outlets operating on an elevated platform. The solution had to provide substantial attenuation while keeping pressure loss low enough to protect fan airflow and heat removal.

 

Engineered Solution

 

  • Added exhaust silencers to all 86 fan outlets, designed for ≥ 25 dB(A) attenuation with total pressure loss ≤ 60 Pa.
  • Used a casing of 2.0 mm galvanized steel with a structural frame, 24 kg/m3 glass wool infill and 0.8 mm galvanized perforated inner facing.
  • Added dual flow-guiding heads and rain-protection acoustic caps to support low-loss discharge and weather resistance.
  • Installed an approximately 498 m long, 7 m high acoustic barrier along the north side of the steel platform, with panel weighted sound insulation Rw ≥ 30 dB.
  • Used 100 mm acoustic splitters with approximately 150 mm spacing; typical silencer dimensions were approximately 1410 x 1820 x 3200 mm including the rain cap.
  • Provided powder-coated flow-guide ends, steel support structures, maintenance walkways and safety protection.

 

Performance Targets And Results

 

Metric

Target or value

Project interpretation

Boundary noise target

Daytime ≤ 70 dB(A); nighttime ≤ 55 dB(A)

Designed for Class IV compliance

Outlet silencer attenuation

≥ 25 dB(A)

Design target

Barrier reduction

Approximately 15-24 dB(A)

Simulation-based range

Pressure loss

≤ 60 Pa

Fan ventilation and heat removal maintained

 