Projects

Boundary Noise Control for a Solar Manufacturing Facility

Sep 22, 2026 Leave a message

A layered solution combining acoustic enclosures, exhaust silencers and a freestanding barrier

The project used a system-level approach rather than treating one noise source in isolation. Enclosure, exhaust silencing and barrier geometry were coordinated around the actual equipment layout and maintenance requirements.

 

Project Profile

 

Location

Zhejiang, China

Industry

Solar and renewable energy manufacturing

Primary noise sources

Process equipment, hot exhaust fans, cooling towers and HVAC equipment

Baseline condition

Boundary noise up to 89 dB(A)

Applicable standard or target

GB 12348-2008 Class III area: daytime ≤ 65 dB(A), nighttime ≤ 55 dB(A)

image001
Before Treatment
image003
After Treatment

Project Challenge

 

Several equipment groups were distributed across different elevations near the southern site boundary. The treatment therefore had to control direct radiation, exhaust noise and elevated noise paths without restricting ventilation or routine inspection.

 

Engineered Solution

 

  • Enclosed the second-floor equipment zone with composite sound-absorbing and sound-insulating modules rated at ≥ 30 dB weighted sound insulation.
  • Added an upward-facing exhaust silencer system for the hot exhaust fans, with a design attenuation of ≥ 20 dB.
  • Installed a 6 m high single-sided acoustic barrier along the boundary-facing side of the first-floor platform.
  • Applied additional absorption and localized enclosure treatment around the top-level equipment area to reduce upward-radiated noise.
  • Integrated acoustic doors, observation windows and maintenance access routes into the enclosure design.

 

Performance Targets And Results

 

Metric

Target or value

Project interpretation

Boundary noise target

Daytime ≤ 65 dB(A); nighttime ≤ 55 dB(A)

Designed for Class III boundary compliance

Overall noise reduction

≥ 24 dB(A)

Target performance

Operations

Ventilation and heat dissipation maintained

Production process not interrupted

 